Tag:power=portal
Jump to navigation
Jump to search
power = portal |
Description |
---|
A supporting structure for power lines, composed of vertical legs with cables between them attached to a horizontal crossarm. |
Group: power |
Used on these elements |
Useful combination |
Status: de facto |
Tools for this tag |
|
A portal is a support composed of 2 or more vertical legs linked by horizontal crossarm supporting the power cables (electrical wires).
Cables are supported inside the legs. If some cables are outside them, it's a h-frame tower and power=tower + design=h-frame should be used.
Standard
Several keys can be used to describe a power portal with details. Please use the following:
Tag | Value | Description | Recommendation |
---|---|---|---|
power | portal | It's a power portal | Mandatory |
ref | Portal reference | Power portal reference as seen in situation | Optional |
height | height | The height of the portal from the ground | Optional |
operator | operator | The power portal operator's name. | Recommended |
structure | lattice, tubular or solid | The structure pattern of the portal | Optional |
design | portal design | The generic design name of the portal without any designer internal reference | Optional |
design:ref | portal design reference | The design reference of the portal. Most of the time operator's internal references. See F44 for example in France. | Optional |
material | material | The material which the portal is made of. | Optional |
colour | portal colour | The colours of the portal, separated with a ; . | Optional |
Mapping as a
Portals can be supported by more than 2 legs. It is possible to map them as when necessarily and relevant.
Here are two examples of the same situation to show how the two way of mapping work.
Case in picture | Location | Comments | Tags |
---|---|---|---|
France | A power portal in an outside power substation and carrying a 225 kV bay line. Mapped as a | ||
A power portal in an outside power substation and carrying a 225 kV bay line. Mapped as a and using power=insulator to link the power line to it. |
For the portal: |